AP Solar Collector General Specifications |
|
Manifold Casing Material |
Powder Coated Aluminium
(grade 3A21)
|
Frame Material |
1.5mm 304 Stainless
Steel
|
Header Pipe Material |
99.93% pure Copper &
lead free 45% silver brazing
|
Insulation |
Compressed Glass Wool -
K = 0.043W/mK
|
Rubber Seals and Rings |
UV stabilized high
temperature silicone rubber
|
Optimal installation angle |
20-70o
Vertical, -5o to +5o
Horizontal
|
Maximum Operating Pressure |
8bar
- 116psi
|
Pressure Drop |
700 Pa @ 3.3L/min for 20
tube manifold (SRCC)
|
Optimal flow rate |
0.1L/min/tube -
0.026G/min/tube
|
Performance Data ( SPF) |
Conversion Factor: ho =
0.717
Loss Coefficients: a1 = 1.52, a2 = 0.0085 |
Model
Specifications
|
|||||
Model
|
AP-Demo
|
AP-10
|
AP-20
|
AP-22
|
AP-30
|
Overall Length (mm / inch) 1 |
660 / 25.9"
|
1980 / 77.9"
|
|||
Overall Width (mm / inch) |
376 / 14.8"
|
796 / 31.3"
|
1496 / 58.8"
|
1636 / 64.4"
|
2196 / 86.4"
|
Overall Height (mm / inch) |
156 / 6.1" (including
flush roof mounting frame)
|
||||
Absorber Area (m2 / ft2) 2 |
0.08 / 0.86
|
0.8 / 8.6
|
1.6 / 17.2
|
1.76 / 18.9
|
2.4 / 25.8
|
Fluid Capacity (ml / ounces) |
190 / 6.4
|
290 / 9.8
|
510 / 17.2
|
550 / 18.6
|
833 / 28.2
|
Gross Area (m2 / ft2) 3 |
0.25 / 2.67
|
1.57 / 16.95
|
2.96 / 31.8
|
3.24 / 34.8
|
4.35 / 46.8
|
Dry Weight (kg / pounds) |
8 / 18
|
35 / 77
|
64 / 140
|
71 / 157
|
95 / 209
|
1. | Length and width do not include the inlet and outlet which protrude from either the rear or ends of the manifold. |
2. | Absorber
area calculated as: D x L x N where: .....D = diameter of the absorber tube, in this case 0.047m .....L = exposed length of tube: For 1.8m tubes this is 1.72m .....N = number of tubes (4, 10, 20, 22, 30) .....Eg. 0.047 x 1.72 x 20 = 1.6m2 absorber area (1m2 = 10.76ft2) |
3. | Calculated simply as overall length (including frame) x overall width. |
4. | AP Models
are named as follows: AP(Manifold Casing Colour)(Port Location) - (Tube Number) Manifold Casing Material: B = Dark Brown, K = Black, S = Silver Port Location: R = Rear, E = End Tube Number: 4, 10, 20, 22, 30 Eg. APKR-20 = black rear port 20 tube manifold. |
F.Y.I. any top menu link will lead you back to a new cascading menu page.
Please submit comments,
suggestions, problems or contact us with our
Copyright ? 2005 No Utility Bills Inc.
All rights reserved.
Last modified: