Type of fuel |
Wood |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Maximum input
capacity |
235,000 BTU (69
kW) |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Blower |
3/4 HP 2 speed
Belt driven, 1800 cfm |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Loading capacity |
Jusqu'?125 lbs
(57 kg) |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Color |
Green |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Exterior dimensions |
34"W x 53"D x
48"H |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Flue spigot
diameter |
8" |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Recommended exhaust
pipe diameter |
8" |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Type of chimney |
2100 degree F (1150 degree C) |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Recommended chimney
diameter |
8" |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Firebox dimensions |
24"W x 28"D x
17"H |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Maximum log length |
27" |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Door opening
dimensions |
12"W x 13"H |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Type of door |
Double plate
steel |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Hot air plenum
dimensions |
32,5"W x 30"D |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Cold air plenum
dimensions |
32,5"W x 19,25"D |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Ash drawer
dimensions |
12"W x 16"D x
3"H |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Number of filters |
2 (steel) |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Filters dimensions |
12"W x 24"D x
1"H |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Minimum clearances
(Front) |
48" |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Minimum clearances
(Back) |
29"
recommended
for servicing |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Minimum clearances
(Sides) |
24"
recommended
for servicing |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Minimum clearances
(Ducts) |
6" for the first
six feet and 2" thereafter |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Recommended
clearance (blower maintenance) |
29" |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Weight |
660 lbs (300 kg) |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Warranty |
Limited lifetime
warranty |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Test standard -
safety |
Can CSA
B366.1-M91, CSAB212-93, UL391 3e Ed. rev.
1999 |
OIL BURNER (OPTIONAL) |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Input capacity |
150,000 BTU (44
kW) |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Burner orifice |
1,0 gal/h (3,79
l/hr.) |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Pump pressure |
120 PSI |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Standard burner |
Beckett AFG |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Efficiency |
82 % |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Burner location |
Right |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Recommended
clearance (Maintenance) |
24" |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Optional insulated
vestibule (Burner) |
No |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Recommended exhaust
pipe diameter |
6" |
![](../../Furnaces/PSG/Images/filetbrun.gif) |
Exhaust pipe
location |
Left |