Floor Protection


Product & installation specifications are subject to change without notice.
Product installation must adhere strictly to the installation manual shipped with product!

The P3 requires one of the following forms of hearth protection
if not installed directly on concrete poured on earth:
1)The factory provided hearth pad can be installed
to satisfy the floor protection requirement,
2) Any ULC, or Warnock Hersey Listed Type 1 hearth board,
3) 20 gauge sheet metal or non-combustible material - ceramic tile, stone, brick, etc..

Factory Hearth Protector Installed

If the factory hearth pad is not installed as per manual instructions,
the unit must be installed with a minimum of 6” of floor protection
in front of and to the sides of the door opening.