PTO 10kW - 24kW
PTO 30kW - 75kW
PTO 110kW- 150kW
PTO 160kW - 500kW
Power take off
generators use the same alternator that Power To Go's "Standard Gensets"
utilize. They
come with a speed gear increaser to get the genset to operate at the
required speed. Depending on required use there are a variety of options
available, so each unit has to be custom designed and quoted.
Power take off
generators are
available in 10, 12, 15, 20, 24, 30, 40, 50, 75, 100, 120, 130, 140,
150, 160, 200, 250, 300 and 500 kW sizes with custom units available.
You will require
approximately 1-1/2 hp for every kilowatt of generator size.
Size
|
10kW |
12kW |
15kW |
20kW |
24kW |
ALTERNATOR
SPECIFICATIONS |
TFW-10KW-4P |
TFW-12KW-4P |
TFW-15KW-4P |
TFW-20KW-4P |
TFW-24KW-4P |
Rated Power (kW)
|
10 |
12 |
15 |
20 |
24 |
Rated Voltage (v)
|
220/120 |
Rated Current (A)
|
41.6 |
50 |
62.5 |
83.3 |
100 |
Rated Frequency (HZ)
|
60 |
Rated Speed (rpm)
|
1800 |
Phase Connection
|
3-Phase, 4-Wire |
Winding Connection
|
Star-connected |
Excitation Method
|
Brushless |
Insulation Method
|
F Class |
Voltage Regulation Method
|
AVR |
Steady-state Voltage regulation Rate
|
1% |
Degree of Protection
|
IP23 |
Return To Top
![Pricing](../buttons/buttonprice.jpg)
Size
|
30kW |
40kW |
50kW |
75kW |
ALTERNATOR
SPECIFICATIONS |
TFW-30-4P |
TFW-40-4P |
TFW-50-4P |
TFW-75-4P |
Rated Power (kW)
|
30 |
40 |
50 |
75 |
Rated Voltage (v)
|
120/240 or 380/220 or 347/600V |
Rated Current (A)
|
90 / 57/36 |
120/76/48 |
150/95/60 |
226/142/90 |
Rated Frequency (HZ)
|
60 |
Rated Speed (rpm)
|
1800 |
Phase Connection
|
3-Phase, 4-Wire |
Winding Connection
|
Star-connected |
Excitation Method
|
Brushless |
Insulation Method
|
F Class |
Voltage Regulation Method
|
AVR |
Steady-state Voltage regulation Rate
|
1% |
Degree of Protection
|
IP23 |
Return To Top
![Pricing](../buttons/buttonprice.jpg)
Size |
110kW |
120kW |
130kW |
140kW |
150kW |
ALTERNATOR
SPECIFICATIONS |
TFW-110KW-4P |
TFW-120KW-4P |
TFW-130KW-4P |
TFW-140KW-4P |
TFW-150KW-4P |
Rated Power (kW)
|
110 |
120 |
130 |
140 |
150 |
Rated Voltage (v)
|
120/240V or 220/380V or 347/600V |
Rated Current (A)
|
331 /209/ 132 |
361/ 228 / 144 |
391 /247 /156 |
421/266 /168 |
451/ 285/ 180 |
Rated Frequency (HZ)
|
60 |
Rated Speed (rpm)
|
1800 |
Power Factor
|
0.8 |
Phase Connection
|
3-Phase, 4-Wire |
Winding Connection
|
Star-connected |
Excitation Method
|
Brushless |
Insulation Method
|
F Class |
Regulation Method
|
AVR |
Steady-state Voltage regulation Rate
|
1% |
Degree of Protection
|
IP23 |
Return To Top
![Pricing](../buttons/buttonprice.jpg)
Size |
160kW |
200kW |
250kW |
300kW |
500kW |
ALTERNATOR
SPECIFICATIONS |
TFW-160KW-4P |
TFW-200KW-4P |
TFW-250KW-4P |
TFW-300KW-4P |
TFW-500KW-4P |
Rated Power (kW)
|
160 |
200 |
250 |
300 |
500 |
Rated Voltage (v)
|
120/240V or 220/380V or 347/300V |
Rated Current (A)
|
481/304/193 |
6601/380/241 |
752/475/301 |
902/570/361 |
1504/950/601 |
Rated Frequency (HZ)
|
60 |
Rated Speed (rpm)
|
1800 |
Power Factor
|
0.8 |
Phase Connection
|
3-Phase, 4-Wire |
Winding Connection
|
Star-connected |
Excitation Method
|
Brushless |
Insulation Method
|
F Class |
Regulation Method
|
AVR |
Steady-state Voltage regulation Rate
|
1% |
Degree of Protection
|
IP23 |
Return To Top
![Pricing](../buttons/buttonprice.jpg)