About UsConditions Of UseFinancingPrivacyTerms Of SalesService & SupportSearchHome PageSpecials & Promotions

Power Take Off Generators Page

PTO 10kW - 24kW         PTO 30kW - 75kW         PTO 110kW- 150kW         PTO 160kW - 500kW

Power take off generators use the same alternator that Power To Go's "Standard Gensets" utilize. They come with a speed gear increaser to get the genset to operate at the required speed. Depending on required use there are a variety of options available, so each unit has to be custom designed and quoted.

Power take off generators are available in 10, 12, 15, 20, 24, 30, 40, 50, 75, 100, 120, 130, 140, 150, 160, 200, 250, 300 and 500 kW sizes with custom units available.

You will require approximately 1-1/2 hp for every kilowatt of generator size.

Size

10kW

12kW

15kW

20kW

24kW

ALTERNATOR SPECIFICATIONS

TFW-10KW-4P

TFW-12KW-4P

TFW-15KW-4P

TFW-20KW-4P

TFW-24KW-4P

Rated Power (kW)

10

12

15

20

24

Rated Voltage (v)

220/120

Rated Current (A)

41.6

50

62.5

83.3

100

Rated Frequency (HZ)

60

Rated Speed (rpm)

1800

Phase Connection

3-Phase, 4-Wire

Winding Connection

Star-connected

Excitation Method

Brushless

Insulation Method

F Class

Voltage Regulation Method

AVR

Steady-state Voltage regulation Rate

1%

Degree of Protection

IP23

Return To Top

Pricing

Size

30kW

40kW

50kW

75kW

ALTERNATOR SPECIFICATIONS

TFW-30-4P

TFW-40-4P

TFW-50-4P

TFW-75-4P

Rated Power (kW)

30

40

50

75

Rated Voltage (v)

120/240 or 380/220 or 347/600V

Rated Current (A)

90 / 57/36

120/76/48

150/95/60

226/142/90

Rated Frequency (HZ)

60

Rated Speed (rpm)

1800

Phase Connection

3-Phase, 4-Wire

Winding Connection

Star-connected

Excitation Method

Brushless

Insulation Method

F Class

Voltage Regulation Method

AVR

Steady-state Voltage regulation Rate

1%

Degree of Protection

IP23

Return To Top

Pricing

Size

110kW

120kW

130kW

140kW

150kW

ALTERNATOR SPECIFICATIONS

TFW-110KW-4P

TFW-120KW-4P

TFW-130KW-4P

TFW-140KW-4P

TFW-150KW-4P

Rated Power (kW)

110

120

130

140

150

Rated Voltage (v)

120/240V or 220/380V or 347/600V

Rated Current (A)

331 /209/ 132

361/ 228 / 144

391 /247 /156

421/266 /168

451/ 285/ 180

Rated Frequency (HZ)

60

Rated Speed (rpm)

1800

Power Factor

0.8

Phase Connection

3-Phase, 4-Wire

Winding Connection

Star-connected

Excitation Method

Brushless

Insulation Method

F Class

Regulation Method

AVR

Steady-state Voltage regulation Rate

1%

Degree of Protection

IP23

Return To Top

Pricing

Size

160kW

200kW

250kW

300kW

500kW

ALTERNATOR SPECIFICATIONS

TFW-160KW-4P

TFW-200KW-4P

TFW-250KW-4P

TFW-300KW-4P

TFW-500KW-4P

Rated Power (kW)

160

200

250

300

500

Rated Voltage (v)

120/240V or 220/380V or 347/300V

Rated Current (A)

481/304/193

6601/380/241

752/475/301

902/570/361

1504/950/601

Rated Frequency (HZ)

60

Rated Speed (rpm)

1800

Power Factor

0.8

Phase Connection

3-Phase, 4-Wire

Winding Connection

Star-connected

Excitation Method

Brushless

Insulation Method

F Class

Regulation Method

AVR

Steady-state Voltage regulation Rate

1%

Degree of Protection

IP23

Return To Top

Pricing

 

Power To Go   Return To Power To Go Main Page
Contact Information

F.Y.I. any top menu link will lead you back to a new cascading menu page.
Please submit comments, suggestions, problems or contact us with our
If the "Email Form" link is not displayed you must enable Java Script to access it!
No Utility Bills Inc. All rights reserved. Last modified: 10/19/24