Floor Protection


Product & installation specifications are subject to change without notice.
Product installation must adhere strictly to the installation manual shipped with product!

The Boston 1200 and 1700 require one of the following forms of hearth protection
if not installed directly on concrete poured on earth:
1) Any UL, ULC, or Warnock Hersey Listed Type 1 hearth board.
2) Any non-combustible material.

In Canada, floor protection must extend 18" from the front of the stove
and 8" from the sides and rear of the stove.

Straight Floor Protector

* Use appropriate column in chart as the Boston 1200 and 1700 have different specs.

Example: Minimum straight floor protector for the Boston 1200 - *40-1/2"w x 46"d
(* the pad is measured to the inside steel stove body not the cast iron side).

Corner Floor Protector

* Use appropriate row in chart as the Boston 1200 and 1700 have different specs.

Example: Minimum corner floor protector for the Boston 1200 - *59-7/8" x 56-5/8" x 28-1/8"
(* the pad is measured to the inside steel stove body not the cast iron side).