Floor Protection


Product & installation specifications are subject to change without notice.
Product installation must adhere strictly to the installation manual shipped with product!

The XXV requires one of the following forms of hearth protection
if not installed directly on concrete poured on earth:
1) Any ULC, or Warnock Hersey Listed Type 1 hearth board,
2) 20 gauge sheet metal or non-combustible material - ceramic tile, stone, brick, etc..

Straight Floor Protector


*In Canada, you may follow smaller U.S. floor protection requirements,
ONLY if the user agrees to completely shut down the appliance,
and allows it to cool to where all fire is extinguished and
the combustion blower and its indicator light shuts off,
prior to opening the firebox door or ash door.

*Floor protection dimensions for the front and sides are measured from the appliance door opening in The United States.
In Canada, the side dimension is measured from the widest part of the appliance.